APC Metered Rack PDUs offer resilient power distribution and actively measure, display, and log volts, amps, real power (kW) & energy (kWh). This PDU offers LCD display, real-time remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. Historical reporting enables users to meter customer power usage, optimize energy use as well as plan for capacity . This zeroU PDU can operate at up to 60 degrees Celsius and can be accessed, configured, and managed remotely via EcoStruxure IT, Web, SNMP and Command Line Interface. Power is supplied to the PDU at 220-240 volts via IEC 309 2P + E plug with a 3m (10 ft) cord while power comes out at 230 volts through (18) C13 and (2) C19 locking outlets. It integrates with EcoStruxure IT, and daisy-chaining is supported to monitoring up to 4 PDUs from 1 IP address as well as a local USB port for easy local firmware updates As a Green Premium product, this unit comes with a verified product environment profile, including carbon footprint, scope 3 emissions and end of life instructions.
APC Easy Metered Rack PDU EPDU1216M is Easy-to-install and easy-to-use PDU, making rack power distribution easy and intelligent. This provides real-time remote monitoring, power management of connected loads, and much more features than the average power strip. EPDU1216M has IEC 309 16A 3P+N+E type inlet, Twenty one IEC C13 and three IEC C19 type outlet sockets. This is vertical rack mountable PDU in ultra light weight and smart, multifunctional new designed display. Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Full-featured user friendly network management web interface provides standards-based management via Web, SNMP, and Command Line Interface. Allows users to access, configure, and manage units from remote locations to save valuable time. Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. The packaging includes installation guide, user manual toolless mounting kit and vertical mounting brackets for quick and easy mounting in the enclosure. This can operate from -5° to +45°C temperation range and comes with 1 year of standard warranty. Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Easy Switched Rack Power Distribution Units (Rack PDU) provide on/off outlet switching, advanced power management, load monitoring and much more features than the average power strip.
CyberPower PDU41005 Switched series power distribution unit provides output from a UPS unit, generator, or utility power to multiple connected devices in datacenter environments. The unit supports remote individual outlet control over the network, allowing administrators to turn on/off connected devices from any location. Administrators can further determine the power sequence used to turn individual outlets on or off. The power management web interface offers real-time remote monitoring of the PDU vitals of the outlets of networked clients. Event logging via a web browser or network connection allows users to review a history of power conditions. When specified power events occur, automatic event notifications will be sent via email, SMS text, or SNMP trap to designated users so that they can take immediate actions. The featured RJ45 port enables the connection of the optional environmental sensor (ENVIROSENSOR), which can provide real-time temperature and humidity monitoring in an IT center. The product is also certified to be interoperable and compatible with Cisco Compatible™ network environments, which helps to achieve the best energy performance possible in the datacenter scenario.
This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty, single-phase, maintenance bypass / power output distribution system. This system, hereafter referred to as the POD, provides high-quality maintenance by pass capability for all micro UPS products up to and including 3kVA.